aerosol filling Production Line: Complete Manufacturing Process Explained
2026-09-19
If your BOV aerosol Filling Machine is running but the liquid material is not coming out, don't worry. In many cases, the problem can be caused by the valve or sealing ring.
Before contacting technical support, follow these 4 simple steps to check the machine.
Step 1: Check the Directional Valve
First, check whether the directional valve is installed in the correct direction.
If the valve is installed incorrectly, the material may not flow normally.
· Stop the machine and release the pressure.
· Check the installation direction of the valve.
· Make sure it is installed according to the original machine configuration.
If the valve is installed correctly but the machine still does not discharge material, continue to Step 2.
Step 2: Check the Sealing Ring of the Angle Seat Valve
Next, check the sealing ring inside the angle seat valve.

The sealing ring is a wear part. After long-term use, it may become worn, damaged, or deformed, which can affect the valve operation and material flow.
Check the sealing ring for:
· Cracks
· Wear
· Deformation
· Hardening or other visible damage
If the sealing ring is damaged, replace it with a new one.
Maintenance Tip: Sealing rings should be checked and replaced regularly. Wejing also provides replacement parts with the machine for routine maintenance.
Step 3: Reinstall the Valve and Connect the Air Tube
After checking or replacing the sealing ring, reinstall the angle seat valve correctly.
Important: Make sure the pneumatic air tube is connected properly.
Check that:
· The valve is installed correctly.
· The sealing ring is positioned properly.
· The air tube is connected.
· The connections are secure.
A disconnected or incorrectly connected air tube can prevent the valve from operating normally.
Step 4: Test the Filling Function
After completing the checks above, start the machine and perform a test filling.

If the liquid material comes out normally, the problem has been resolved.
If there is still no material output, the problem may be related to the material pipeline, pneumatic system, pump, or another component. In this case, contact the machine manufacturer for further technical support.
Basic Maintenance Tip
To keep your BOV aerosol filling machine running smoothly:
① Check sealing rings regularly and replace worn parts.
② Keep the material pipeline and valve clean.
③ Check pneumatic tubes and connections for leakage.
④ Keep commonly used sealing parts as spare parts.
Regular maintenance can help reduce unexpected downtime and keep the filling process stable.
Quick Check
Directional valve → Sealing ring → Air tube → Test filling
Follow these four steps first when your BOV aerosol filling machine is not filling.