Leave Your Message

Semi-Automatic BOV Aerosol Filling Machine Crimping Improperly? 

 2026-10-22

Is your semi-automatic BOV aerosol filling machine not inflating properly? Incorrect inflation pressure, an unsuitable inflation time, or air leaks in the piping may affect filling performance.

As an aerosol filling machine manufacturer, Wejing explains three common causes of incorrect inflation pressure and how to troubleshoot them.

1. Common Pressure Problems and Solutions

(1) Incorrect Inflation Pressure

Problem: If the inflation pressure is too high or too low, the machine may not inflate the BOV aerosol can correctly.

Solution: Adjust the pressure regulator.

① Locate the inflation pressure regulator on the right side of the inflation and crimping unit.

② Check the pressure gauge to read the current inflation pressure.

③ Pull the regulator knob upward before turning it.

④ Adjust the knob until the pressure reaches the required setting.

For many semi-automatic BOV aerosol filling machines, the typical working pressure is 0.6–0.7 MPa (6–7 bar). Always follow the pressure requirements specified for your machine configuration.

(2) Incorrect Inflation Time

Problem: If the inflation time is too short, the can may not reach the required pressure. If the setting is unsuitable, inflation performance may become inconsistent.

Solution: Adjust the inflation time on the touchscreen.

① Open the relevant parameter settings on the machine's touchscreen.

② Locate the inflation time setting.

③ Adjust the value according to the machine configuration and process requirements.

④ Run a test and check whether the inflation result meets your requirements.

Make small adjustments and verify the results before resuming normal production.

(3) Air Leaks in the Inflation Piping

Problem: Leaks in the air supply line, tubing, or connections may cause pressure loss and prevent the machine from maintaining the required inflation pressure.

Solution: Inspect and repair the leaking piping.

① Stop the machine and safely isolate the air supply before inspection.

② Check the inflation piping, connectors, and joints for leaks or loose connections.

③ Tighten loose connections where appropriate and replace damaged tubing or fittings.

④ Restore the air supply safely and check whether the system maintains the required pressure.

If the pressure continues to drop, inspect the air supply system further or contact Wejing technical support.


2. How to Confirm the Pressure Problem Is Resolved

After making adjustments, run a test using compatible BOV valves and aerosol cans.

Pressure: Confirm that the gauge shows the required working pressure.

Inflation time: Verify that the selected setting meets the process requirements.

Air supply: Check that there are no leaks or abnormal pressure drops.

Filling performance: Confirm that the machine operates consistently during testing.


3.Contact Wejing Technical Support

If the pressure problem persists after checking the regulator, inflation time, and piping, further inspection may be needed.

Wejing specializes in aerosol filling machinery, including semi-automatic BOV aerosol filling machines. When contacting our technical support team, provide your machine model, pressure gauge readings, parameter settings, and a description or video of the problem.

Need help troubleshooting your BOV aerosol filling machine? Contact Wejing for technical support.

Contact us